| AW10, 12 and 14 are MillerEdge's
air wave switch systems. Each system consists of an air
pressure wave which is led, via a hose or pipe, to a
diaphragm contact. This contact converts the positive or
negative pressure wave respectively into an electrical
contact and pulse. The contact is of short duration, due
to the fact that the overpressure escapes through a
valve opening. |
|
|
 
|
|
- Electrical Configuration: 2-wire, N.O. (Optional
N.C.)
- Terminal Configuration: .187” Q.C. Tabs
- Diaphragm: Silicone
- Contact Material: Silver Plated
- Mechanical Life: Min 2 million operations
- Electrical Life: 1 million operations, dependent
on contact load
- Max. Contact Load: .5A/220VAC; 1A/48VDC
- Max. Switch Freq: 25/second
- Max. Pneumatic Load: 2,000mm (78.7”) water column
- Sensitivity: 2mm to 500mm (.078” to 19.7”) water
column
- Ambient Temp. Range: -45°C to +82°C (-49°F to
+180°F)
Enclosure
- Enclosure Material: Polycarbonate
- Tubing: Silicone, 1 Ft. x 3/32” I.D.
- Air Connection: Barbed Coupler 3/32” I.D. US
Patents: #4,905,483 #6,040,536
|
|